PULCOM V9
In-process
Post-process
Digital gauge
LVDT gauge
RoHS compliant
Control unit for in-process and post-process measurements

PULCOM V9

Features

Multipoint measurement

Up to 32 items can be measurement by up to 16 gauges.

Flexible system configuration

Easily change the unit configuration by changing the Condition file.
(Example)When an AE sensor is added to a simple auto sizing system.

PULCOM V9 Multipoint measurement

Support Field Bus

Support for CC-Link, PROFIBUS and DeviceNet significantly simplifies wiring. Ideal for acquiring measurement data required when integrating with IoT.

PULCOM V9 Support Field Bus

2 types of mounting configuration

Separate type and Box type are available, giving the choice of just placing it over the machine or integrating with the machine panel.
Moreover, a unit from the Separate type can be used as an expansion of the Box type.

Comprehensive screen layouts

Comprehensive screen layouts

External view

External view
External view
External view
External view

Specifications

✓:Available  ー:Not available

Basic specifications
Product name PULCOM V9
Representative model E-PV9xxx
Use In-process/Post-process
Display method 5.7-inch QVGA color LCD
Display items Measurement result, Item list, Settings
Display range of measurement data Select from ±10 μm, ±20 μm, ±50 μm, ±100 μm, ±500 μm, ±800 μm, ±2000 μm, and ±5000 μm
Resolution Select from 0.01 μm, 0.05 μm, 0.1 μm, 0.5 μm and 1 μm
Display unit μm, mm
Human interface Resistive touch panel
Sampling speed 1 msec
Data update time 8 msec
Display separation / panel-type model
IP code BOX Type: IP54 equivalent (front panel only)
Ambient usage temperature /Humidity 0 to 50°C / 10 to 90% R.H. (no condensation)
Vibration resistance/Shock resistance JIS C1003 compliance
CE mark Compliant (Panel Type only)
Outer dimensions (W) × (D) × (H) / weight BOX Type: 170 x 240 x 152 mm/3.5 kg
Power source / power consumption AC85 to 250 V
Accessories Fuse/power cable
External I/F
I/O
Ethernet
RS-232C
Analog input
HLS
Fieldbus
External memory
CF
USB
Main functions/Options
No. of connected detectors 4
No. of expansion gauges 16
No. of measuring items (max) 32
Judgment output 7 level

Options

Options
Product code Product name Model Remarks
0937003 PULCOM
V9 LVDT
E-PV9U00 Unit: LVDT 4 CH connection
0937004 PULCOM
V9 I/O
E-PV9U10 Unit: I/O1 compatible, input 16 points, output 32 points
0937005 PULCOM
V9 CTR
E-PV9U20 Unit: CTR 4 CH connection
0937006 PULCOM
V9 CC
E-PV9U30 Unit: CC-Link 4 station occupied
0937007 PULCOM
V9 PB
E-PV9U31 Unit: PROFIBUS
0937009 PULCOM
V9 DN
E-PV9U33 Unit: DeviceNet
0937050 I/O port E-PV9B10 Expansion board: I/O, input 16 points, output 32 points
0937051 CTR board E-PV9B20 Expansion board: Scale 4 CH connection
0937052 CC-Link board E-PV9B30 Expansion slot for Box Type
0937053 PROFIBUS board E-PV9B31 Expansion slot for Box Type
0937055 RS-232C E-PV9B39 Expansion slot for Box Type
0937056 RS-232C E-PV9B09 LCD unit options
0937057 DeviceNet board E-PV9B33 Expansion slot for Box Type
0937060 24 V power cable 6 m Common power cable for units
0937068 24 V power cable custom 1 m Length specification (in meters)
0937069 24 V power cable 10 m Common power cable for units
0937061 CC-Link cable 1 m Dedicated cable for CC-Link
0937062 CC-Link cable custom 1 m Length specification (in meters)
0937063 V9 connection
cable 0.5 m
Dedicated cable for the units 0.5 m
0937064 V9 connection
cable 3 m
Dedicated cable for the units 3 m
0937065 V9 connection
cable 6 m
Dedicated cable for the units 6 m
0937066 V9 connection
cable 10 m
Dedicated cable for the units 10 m
0937067 V9 connection
cable cuntom
length
Length specification (in meters)
0930154 V11 termination cable Inter-unit communications termination resistor
0937076 DeviceNet cable 1 m DEVICE
NET 1M
Dedicated cable for DeviceNet
0937077 DeviceNet cable custom 1 m SP PER 1M Length specification (in meters)
0937080 PROFIBUS cable 1 m Dedicated cable for PROFIBUS

Contact a Sales Office for more details.

Options
Product code Product name Model Remarks
0937081 PROFIBUS cable custom 1 m Length specification (in meters)
0937082 Auto CAL E-PV9S01 Calibration by an external input
0937083 Zero shift E-PV9S02 For in-process: Function that monitors and compensates zero point finished dimensional drift
0937084 Statistical processing E-PV9S03 Only statistical display
0937085 Post memory E-PV9S04 For post-process: Function that adds MAX, MIN, P-P
0937086 P-memory E-PV9S05 Internal / Auto / External
0937087 Size shift D6 E-PV9S06 Supported different diameters: up to 6D (diameter)
0937088 Repeat counter E-PV9S07 For post-process: Function that monitors finished dimensional displacement and feeds back to processing machine
0937089 Real time calculation E-PV9S08 For in-process: Function that predicts and compensates finished variations
0937090 P100 Integral memory E-PV9S09 Internal / Auto / External
0937091 P110 Integral memory E-PV9S10  
0937092 Average calculation E-PV9S11 Used to measure the average value of a machined workpiece in a given time
0937094 Size shift D20 E-PV9S13 Supported different diameters: up to 20D (diameter)
0937095 Size shift D21 E-PV9S14 Supported different diameters: 21D (diameter) to 40D
0937096 GE-11 connection E-PV9S15 GE-11 connection software
0937097 CTR size shift E-PV9S16 Supported different diameters for digital gauge, up to 40D (diameter)
0937098 Computer link E-PV9S17 Computer link communication
0937099 BCD grade E-PV9S18 External grade by BCD input
0937200 Scale out E-PV9S19 Scale out display
0937201 Outlier filter E-PV9S20 Filter for outlier value
0937202 P120 Integral memory E-PV9S21 Filter for rear fork gauge
0937203 Work pass E-PV9S22 For post-process: Function that triggers measurement with workpiece pass-through
0937204 Inch display E-PV9S23 Inch display function (only available for specific applications or overseas use)
0937205 Data transfer E-PV9S24 Data transfer on the fieldbus
0937206 BCD grade E-PV9S25 Corrected value input function with external BCD, 3 digits or more
0937500 DataLink X Windows data acquisition software
0937070 NT ADAPTER V9H86
A063583
Conversion adapter for size shift gauge